Free Ground Shipping on Orders Over $500* — Limited Time
Marine NMEA 2000 Surge Protector

SPN2K-12DA NMEA 2000 Power Cable Surge Protector for 12VDC Marine Electronics

$149.00

The Bad Wolf SPN2K-12DA is a marine NMEA 2000 power cable surge protector designed to help protect the 12VDC power feed of compatible NMEA 2000 networks from damaging voltage spikes, induced surges, and onboard power disturbances.

It installs inline between the NMEA 2000 power cable and the network T-connector to help reduce the risk of surge energy entering the network power circuit. This model protects the power connection only and does not provide data-line surge protection.

SKU: SPN2K-12DA Category: Tags: , Brand:

The Bad Wolf SPN2K-12DA is a marine NMEA 2000 power cable surge protector designed to help protect the 12VDC power feed of compatible NMEA 2000 marine networks.

Modern marine electronics depend on clean, reliable network power. Voltage spikes, induced voltage, electrical switching, onboard power disturbances, and nearby lightning activity can create damaging surge events on the 12VDC power side of an NMEA 2000 network. The SPN2K-12DA helps reduce the risk of surge damage entering through the network power feed.

Designed for NMEA 2000 Power Protection

The SPN2K-12DA installs inline between the NMEA 2000 power cable and the T-connector on the backbone. This allows the surge protector to help protect the 12VDC network power connection before surge energy can travel farther into the NMEA 2000 system.

This model is designed for power-side surge protection only. It does not provide data-line surge protection. For protection of both NMEA 2000 power and data/CAN bus lines, use the Bad Wolf SPN2K-12BA backbone surge protector.

Key Features

  • Designed for compatible 12VDC NMEA 2000 marine networks
  • Helps protect the NMEA 2000 12VDC power feed from damaging surge events
  • Installs inline between the NMEA 2000 power cable and T-connector
  • One male and one female NMEA 2000 connector
  • 5A continuous current rating
  • 6kA surge current rating
  • Suitable for indoor and outdoor marine applications
  • No serviceable parts

Common Applications

  • NMEA 2000 power cable surge protection
  • Marine electronics network power feeds
  • Chartplotter and display networks
  • Autopilot networks
  • VHF, AIS, sensor, and monitoring networks using NMEA 2000 power

For best results, install according to the product instructions and verify that the NMEA 2000 network is properly powered and terminated.

Product Details

Weight10 oz
Dimensions3.5 × 3.6 × 1 in
Application

Marine

Connection Type

NMEA 2000

Continuous Current Rating

5

Environmental Rating

Indoor, Outdoor

Surge Current Rating (A)

6kA

Voltage (Vdc)

12

Type of Electrical Current

DC

Installation

Professional marine installation is recommended. Installation should be performed by a qualified licensed marine installer in accordance with the product instructions, applicable marine electrical standards, and local requirements.

Always turn off power to the NMEA 2000 network before installation and verify that power has been disabled before working on the circuit or connected equipment.

NMEA 2000 Power Installation Notes

  • The SPN2K-12DA is designed to help protect the 12VDC power side of a compatible NMEA 2000 network.
  • This model protects the NMEA 2000 power connection only. It is not designed to provide data-line surge protection.
  • Locate the best mounting position to allow proper connection into the existing NMEA 2000 network.
  • Mount the surge protector in a dry location and out of direct sunlight for best performance.
  • This device is supplied with one male and one female NMEA 2000 connector.
  • Both NMEA 2000 connectors must be connected to cables or fittings to help maintain a watertight connection.
  • Using installer-supplied NMEA 2000 cables or fittings, connect the male and female connectors to the appropriate network connections.
  • Make sure all connections are secure and that the installation does not create any safety hazards.
  • Restore power after installation and verify that the connected NMEA 2000 equipment operates normally.

Important NMEA 2000 Notes

  • The SPN2K-12DA is designed to be powered by an existing 12VDC NMEA 2000 power connection.
  • Verify the correct voltage application before installing this device.
  • The NMEA 2000 backbone should be properly powered and terminated according to NMEA 2000 network requirements.
  • Do not connect an NMEA 2000 network to power in more than one location unless a proper power isolator is used between the power connections.
  • Do not perform a Hi-Po test on this surge protector. Hi-Po testing may damage the device and void the warranty.

Installer-Supplied Items

The installer or customer must supply any required NMEA 2000 cables, T-connectors, fittings, mounting hardware, tools, or additional materials needed for the installation.

Service and Warranty Note

This product contains no serviceable parts. Tampering with the device may void the warranty. After installation, register the product on the Bad Wolf website to activate the warranty.

Refer to the SPN2K-12DA installation instructions for complete installation details, specifications, and NMEA 2000 network considerations.

Warranty

Bad Wolf surge protection devices include a 5-year product warranty.

Eligible products may also include connected equipment warranty coverage when properly installed and registered according to the warranty terms.

Please review the full warranty terms for complete details, limitations, registration requirements, and coverage information.

FAQ

What is the SPN2K-12DA mainly used for?

The SPN2K-12DA is used to help protect 12VDC NMEA 2000 networks and similar manufacturer networks that use the same style connectors.

What does “12DA” mean?

The “12DA” version is designed for 12VDC NMEA 2000 power connection applications only. It should not be used on any voltage other than 12VDC.

Where is the SPN2K-12DA installed?

The SPN2K-12DA is installed between the 12VDC power source and the NMEA 2000 backbone. The power cable from the 12VDC power source connects to the input side of the surge protector, and a user-supplied NMEA 2000 drop cable connects between the surge protector and a T-connector on the NMEA 2000 backbone.

Is the SPN2K-12DA for 12VDC systems only?

Yes. The SPN2K-12DA is designed for 12VDC NMEA 2000 network power applications only. Do not use this surge protector on 24VDC systems, AC power, or any other voltage.

What does the 6KA rating mean?

The 6KA rating refers to the surge current capacity of the device. The SPN2K-12DA is designed to help protect compatible 12VDC NMEA 2000 network power circuits from damaging surge events.

What equipment can the SPN2K-12DA help protect?

The SPN2K-12DA helps protect the 12VDC power feeding a NMEA 2000 network, which may include connected chartplotters, MFDs, fish finders, autopilots, NMEA 2000 sensors, engine gateways, GPS antennas, and other compatible networked marine electronics.

Does the SPN2K-12DA protect the NMEA 2000 data lines?

No. The SPN2K-12DA is designed to protect the power conductors at the NMEA 2000 network power connection point. It is not designed to protect the CAN/data conductors directly.

Is the SPN2K-12DA plug and play?

Yes. The SPN2K-12DA is designed as a plug-and-play surge protector for compatible 12VDC NMEA 2000 network power connections. No cutting or splicing is normally required when used with the correct matching cables and connectors.

Do I need a separate NMEA 2000 drop cable?

Yes. A user-supplied NMEA 2000 drop cable is used between the SPN2K-12DA and a T-connector on the NMEA 2000 backbone.

Can the SPN2K-12DA be mounted in any direction?

Yes. The SPN2K-12DA can be mounted in any direction and is bidirectional.

Does the SPN2K-12DA have status lights?

No. The SPN2K-12DA does not have status indicator lights.

Is the SPN2K-12DA waterproof?

The device itself is waterproof, but a NMEA 2000 network should not be exposed to direct moisture. Install the surge protector and network connections in a protected location whenever possible.

Can this be used on manufacturer networks similar to NMEA 2000?

Yes, the SPN2K-12DA may be used on similar manufacturer networks that use the same style connectors and compatible 12VDC network power configuration. Always verify compatibility before installation.

Can the SPN2K-12DA be used on 24VDC networks?

No. The SPN2K-12DA is for 12VDC applications only. Do not use it on 24VDC networks or any voltage other than 12VDC.

Can the SPN2K-12DA be used on AC power?

No. The SPN2K-12DA is for 12VDC NMEA 2000 network power applications only and should never be used on AC electrical circuits.

Who should install this product?

This product should be installed by someone familiar with NMEA 2000 networks, marine electronics, and 12VDC electrical systems. When in doubt, consult a qualified marine electronics installer or technician.

Does this product include a warranty?

Bad Wolf surge protection devices include a 5-year product warranty. Eligible products may also include connected equipment warranty coverage when properly used and registered according to the warranty terms.

Specifications

SPN2K-12DA Specifications

Model NumberSPN2K-12DA
Product TypeNMEA 2000 power cable surge protector
ApplicationCompatible 12VDC NMEA 2000 marine networks
Protected Circuit12VDC NMEA 2000 power circuit only
Data-Line ProtectionNot included on this model
Installation TypeInline connection between the NMEA 2000 power cable and the network T-connector
Operating Voltage12VDC
Maximum Voltage16VDC
Continuous Current Rating5A
Surge Current Rating6kA
Connectors1 male NMEA 2000 connector / 1 female NMEA 2000 connector
Operating & Storage Temperature-4°F to +158°F (-20°C to +70°C)
ServiceabilityNo serviceable parts

NMEA 2000 Network Notes

  • The SPN2K-12DA is designed to be powered by an existing 12VDC NMEA 2000 power connection.
  • This model protects the NMEA 2000 power connection only and does not provide data/CAN bus surge protection.
  • The NMEA 2000 backbone should be properly powered and terminated at both ends of the network.
  • NMEA 2000 devices should connect to the backbone using proper T-connectors.
  • Do not connect an NMEA 2000 network to a power source greater than 12VDC.
  • Do not power the NMEA 2000 network from more than one location unless a proper power isolator is used between the power connections.
  • Do not perform a Hi-Po test on this surge protector. Hi-Po testing may damage the device and void the warranty.

Specifications are subject to change. Refer to the product label and installation instructions for complete product-specific ratings and installation requirements.