MAX EMP DEFENDER 12V GEN2 MAXEMP12V
$425.00
- Use on 12V DC battery electrical systems only
- Unique 3 stage surge protection with reverse polarity surge protection
- 500kA surge current rating (Most Powerful 12V Surge Protector On The Market)
- Fast 3ns response time
- Class leading 8 awg wire
- Protects against all Transient Voltage spikes including Lightning, EMP and Solar Flare
- Green Light = Protected, the surge protector is monitoring your electrical system
- Red Light = Unprotected, the surge protector is damaged and needs to be replaced
- Overwatch Protection Circuit
12V DC Vehicle EMP protector rated at 500,000 amps of surge protection
Bad Wolf DC surge protection device SPD provides overvoltage protection. Built using our patented Overwatch protection circuitry that provides ultra-fast surge response and easy to read status indication.
Max EMP Defender 12V Gen 2
The SPD is built to handle surge currents up to 500,000 Amps (500kA). Designed using Metal Oxide Varistors (MOV), Transient Voltage Suppression (TVS) Diodes and Gas Discharge Tube (GDT) technology. With reaction speeds in the trillionth of a second and capable of surviving thousands of repetitive surges when we say this device is built tough that is an understatement. By using Military and Commercial grade components this SPD is designed to protect against every type of transient surge possible including EMP all phases, CME (coronal mass ejection), Solar Flare, Lightning and more...
Bad Wolf is a leader in high power surge protection devices SPDs and provides one of the largest selections of both AC or DC available. Bad Wolf is a Service-Disabled Veteran Owned Made in the USA company that is not only a contract manufacturer for private and federal agencies, but also backed by the SBA (small business administration) to provide custom solutions for consumer applications as well.
Product Details
| Weight | 10 oz |
|---|---|
| Dimensions | 5.5 × 3.25 × 2 in |
| Application | ATV, UTV, Motorcycle and more.., Commercial, Drone, Farm, Generator, Home, Irrigation, Marine, RV, Solar, Vehicle, Wind |
| Connection Type | Ring Terminal |
| Surge Type Category Rating | EMP (E1, E2 and E3 Phase), Lightning, Solar Flare (CME) |
| Environmental Rating | Indoor, Outdoor |
| Product Dimensions | 5.5"X3.25"X2" |
| Product Weight | 10oz |
| Service Type | DC Battery |
| Surge Current Rating (A) | 500kA |
| Type of Electrical Current | DC |
| Voltage (Vdc) | 12 |
Specifications
Review the product details and product description for voltage, surge current rating, connection type, enclosure rating, wiring details, certifications, and other technical information.
For detailed product-specific ratings, refer to the specifications listed on this product page and any available product documentation.
Installation
Surge protection devices are recommended to be installed by a qualified electrician, licensed contractor, or qualified installer in accordance with the product instructions, applicable electrical codes, and local requirements.
Always disconnect power before installation and verify the product is suitable for the electrical system where it will be installed.
Warranty
Bad Wolf surge protection devices include a 5-year product warranty.
Eligible products may also include connected equipment warranty coverage when properly installed and registered according to the warranty terms.
Please review the full warranty terms for complete details, limitations, registration requirements, and coverage information.
FAQ
What is the MAXEMP12V mainly used for?
The MAXEMP12V is designed to help protect 12VDC battery-powered electrical systems from damaging surge events. Its primary application is vehicle protection, but it can also be used on compatible 12VDC battery circuits in marine, RV, generator, emergency power, communications, and other low-voltage DC applications.
What voltage is the MAXEMP12V designed for?
The MAXEMP12V is designed for 12VDC electrical systems only. Do not use this device on AC power, 24VDC systems, or any voltage outside the product rating.
What does the 500KA rating mean?
The 500KA rating refers to the surge current capacity of the device. The MAXEMP12V is designed for customers who want a higher-capacity 12VDC surge protection option for compatible battery-powered electrical systems.
How is the MAXEMP12V different from the MEMP12V?
The MAXEMP12V is the higher-capacity version of the MEMP12V. Both products are designed for compatible 12VDC battery-powered electrical systems, but the MAXEMP12V has a 500KA surge current rating compared to the 150KA surge current rating of the MEMP12V.
Does the MAXEMP12V protect against EMP, CME, solar flare, and lightning-related surges?
Yes. The MAXEMP12V is designed to help protect compatible 12VDC systems against normal surge events, indirect lightning-related surge activity, and EM-related surge events such as EMP, CME, and solar flare related electrical disturbances.
Where should the MAXEMP12V be installed?
The MAXEMP12V is recommended to be connected directly to the battery terminals for best protection. If battery installation is not possible, it may be connected to another suitable section of the 12VDC electrical circuit.
Can the MAXEMP12V be used on vehicles?
Yes. Vehicles are the primary application for the MAXEMP12V. It is designed to connect to a compatible 12VDC vehicle battery circuit to help protect the vehicle’s electrical system from damaging surge events.
Can the MAXEMP12V be used on boats, RVs, generators, or other 12VDC battery systems?
Yes. The MAXEMP12V may be used on compatible 12VDC battery circuits in marine, RV, generator, off-grid, communications, and emergency equipment applications when installed according to the product instructions and voltage rating.
How is the MAXEMP12V wired?
The MAXEMP12V has two wires. The red wire connects to the positive side of the 12VDC circuit, and the black wire connects to the negative side of the 12VDC circuit.
Does the MAXEMP12V connect to chassis ground?
No. The MAXEMP12V connects only to the positive and negative sides of the 12VDC electrical circuit. On a vehicle, the chassis is already connected to the negative battery terminal. Adding a third chassis ground wire could create a ground loop and cause electrical issues.
Is polarity important when installing the MAXEMP12V?
Yes. The MAXEMP12V is polarized. The red wire must be connected to positive, and the black wire must be connected to negative. Always verify polarity before connecting or energizing the circuit.
What do the indicator lights mean?
The MAXEMP12V includes green and red indicator lights. Green means the surge protector is functioning correctly. Red means the surge protector needs to be replaced.
Does the MAXEMP12V need a fuse or circuit breaker?
No additional fuse or circuit breaker is required specifically for the MAXEMP12V because it connects in parallel with the electrical circuit and includes built-in overcurrent protection. Always make sure the vehicle or 12VDC electrical system has proper circuit protection for the overall installation.
Can the MAXEMP12V be installed outdoors?
The MAXEMP12V is waterproof and suitable for harsh environments, but it should not be submerged in water. Install it in a secure location where it will not be exposed to physical damage or improper use.
Can the MAXEMP12V be submerged in water?
No. Do not submerge the MAXEMP12V in water. Although the device is waterproof, it should be installed and used in a way that prevents submersion or damage.
Can the MAXEMP12V be used on AC power?
No. The MAXEMP12V is for 12VDC electrical systems only. Do not use this device on AC power.
Can the MAXEMP12V be used on 24VDC systems?
No. The MAXEMP12V is designed for 12VDC systems only. Do not use it on 24VDC systems or any voltage outside the product rating.
Can the MAXEMP12V be opened or modified?
No. Do not open, modify, tamper with, or improperly use the MAXEMP12V. If the device is damaged, improperly connected, or indicates replacement is needed, it should be replaced.
Who should install this product?
This product should be installed by someone familiar with 12VDC electrical systems, vehicle batteries, polarity, and the equipment being protected. When in doubt, consult a qualified technician, mechanic, marine technician, RV technician, or installer.
Does this product include a warranty?
Bad Wolf surge protection devices include a 5-year product warranty. Eligible products may also include connected equipment warranty coverage when properly installed and registered according to the warranty terms.







